| Device name |
Personal Alert Safety System (PASS) |
A wearable safety device designed to alert nearby personnel when a firefighter is in distress or has stopped moving. |
| Primary purpose |
Local emergency notification |
Provides an audible and, depending on the design, visual or tactile alert to help rescuers locate an incapacitated or endangered wearer. |
| Manual activation |
Activated by pressing the emergency or alarm control |
Allows the wearer to intentionally signal distress, even when the motion-sensing function has not activated. |
| Automatic activation |
Triggered by a period of detected inactivity |
The device normally provides a pre-alarm warning before entering full alarm, allowing the wearer to cancel a false activation. |
| NFPA 1982 sound level |
At least 95 dBA measured at 3 meters |
The high sound output is intended to remain noticeable in noisy, smoky, and equipment-filled emergency environments. |
| Alarm pattern |
A repeating, distinctive audible alert |
A recurring pattern helps distinguish a PASS alarm from ordinary background sounds and equipment noise. |
| Pre-alarm function |
Short warning period before full alarm |
Gives the wearer an opportunity to move or reset the device if inactivity was intentional. |
| Motion sensing |
Electronic detection of movement and inactivity |
Supports automatic alarm initiation when the wearer may be unconscious, trapped, or otherwise unable to call for help. |
| Reset or cancellation |
Movement or a designated control sequence, depending on device configuration |
Helps prevent unnecessary full alarms while preserving rapid activation during a genuine emergency. |
| Additional alert methods |
May include visual indicators and vibration |
Supplementary alerts can assist in low visibility or high-noise conditions, but they do not replace the required audible alarm. |
| Power source |
Replaceable or rechargeable battery, depending on device design |
Battery condition must be checked regularly because insufficient power can affect alarm performance. |
| Low-battery indication |
A dedicated warning signal or status indication |
Alerts the user or safety team that the battery requires replacement, charging, or inspection. |
| Typical mounting location |
Outer protective clothing, harness area, or another approved accessible position |
The location should keep the alarm audible and allow the wearer to reach the controls while minimizing accidental activation. |
| Environmental use |
Intended for demanding emergency-service conditions when used within its certification and operating limits |
Users must follow the equipment instructions for heat exposure, water resistance, cleaning, inspection, and storage. |
| Routine inspection |
Functional test before use and scheduled maintenance |
Testing should confirm alarm sound, controls, motion sensing, battery status, attachment hardware, and visible damage. |
| Important limitation |
A PASS device is a local alert system, not a complete rescue system |
Effective emergency procedures, accountability, communications, training, and rapid rescue response remain essential. |