Leave Your Message

Firefighter PASS Devices: GB 27900 vs NFPA 1970 vs ATEX — Choosing the Right Standard and the Right Manufacturing Partner

2026-10-29

 Why PASS Device Standards Are a Sourcing Decision, Not Just a Technical One

A firefighter PASS device can look similar across catalogs, but the standard behind it decides whether it can legally enter your market, pass your tender review, and be accepted by the end user. In China, GB 27900—2026 is the product performance baseline. In North America and NFPA-referenced projects, NFPA 1970 (2025) — which now carries the PASS requirements formerly in NFPA 1982 — is the language buyers use. In explosive atmospheres, ATEX 2014/34/EU is a separate legal admission requirement, not a performance standard.

Choosing the wrong path is not a price problem. It is a compliance problem. This guide compares the three frameworks, explains what the differences mean for buyers, and shows how our GB-compliant and ATEX-certified PASS devices — backed by an in-house laboratory and factory-direct customization — can be matched to your market.

GB 27900—2026 vs NFPA 1970 (2025) vs ATEX: A Quick Comparison

Comparison GB 27900—2026 NFPA 1970 (2025, PASS section) ATEX 2014/34/EU
Nature Chinese national product standard U.S. fire service product standard EU legal directive for explosive atmospheres
Market China fire procurement North America and NFPA-referenced projects EU and ATEX-referenced international projects
Device logic Standard type / communication type (public, private, satellite) Stand-alone / integrated / RF PASS Equipment group and category, e.g. II 1G
Core scope Alarm + communication + sensing expansion Audible/visual alarm + RF distress and evacuation communication Does not define PASS performance; controls explosion safety
Acoustic reference Strong alarm ≥100 dB(A); pre-alarm ≥80 dB(A) Commonly referenced ≥92 dBA; muffle test for worn-position attenuation No acoustic performance requirement
Environmental focus IP68, 72 h salt spray, -25°C low temperature 260°C/5 min heat, 3 m drop, flame resistance Ignition protection, temperature class
Hazardous area Separate Ex-proof certificate under GB 3836 Non-incendive Class 1, Division 2 in 2025 edition II 1G Ex ia covers Zone 0/1/2

Buyer takeaway: GB 27900 tells you what performance a PASS device must deliver in China. NFPA 1970 tells you what the North American fire service expects. ATEX tells you whether the device is legally allowed into an explosive atmosphere at all. They are parallel paths, not substitutes.

What the Differences Mean for Buyers

Acoustics. GB 27900—2026 sets a higher bare-device sound pressure threshold, which matters in fireground noise. NFPA’s muffle test reminds buyers that “dB at 3 m” and “audibility when worn” are different questions. Ask any manufacturer how the device performs in the worn position, not only on a test bench.

Environmental testing. GB’s IP68 and 72 h salt spray coverage is directly relevant to wet, coastal, tunnel and water-rescue scenarios. NFPA’s 260°C/5 min heat and 3 m drop reflect flashover exposure and dropped-device scenarios. The right question is not “which standard is stricter,” but “which test scenario matches my market.”

Communication. NFPA RF PASS solves one problem well: sending a distress signal from the firefighter to a base station. GB 27900—2026 communication-type devices go further into platform integration: positioning, video, thermal imaging, gas detection and command-center data. These are different system layers and different budget lines.

Operating time and Visibility. For ATEX environments, extended alarm endurance and high-visibility lighting are critical. For example, our ATEX-certified PAU-10 provides ≥450 minutes of continuous alarm, while the lightweight PAU-20 provides ≥400 minutes with an ultra-bright ≥750 cd/m² visibility for long-duration rescue missions. Always confirm the figure against the final test report for the specific model.

 

GB-Compliant Models

PASS device 1.png

Model Positioning Key Features
RHJ800T/S Intelligent thermal-imaging rescue single-soldier PASS GB 27900-compliant; domestic Ex-proof certified; integrated IR thermal + visible dual lens; see through smoke to locate heat sources; on-site video recording and voice intercom; Bluetooth expansion, compass and auxiliary lighting; satellite positioning and real-time data transmission
RHJ-680TR Search-and-rescue PASS with rear control terminal GB 27900-compliant; domestic Ex-proof certified; linked alarm response; automatically receives group SOS and provides locating; optional heart-rate wristband, gas monitor and smart SCBA; data to command center; access to big-data management platform; group evacuation commands; event data logging
RHJ1800/A Long-duration rugged PASS GB 27900-compliant; domestic Ex-proof certified; ≥1800 min continuous alarm; high-strength polycarbonate housing; self-test on power-on; audible + visual alarm; fireground timer; direction light >300 cd/m²; ambient temperature alarm above 80°C; battery display and low-battery alarm; IP68
RHJ500/B Simple, high-visibility PASS GB 27900-compliant; domestic Ex-proof certified; ≥500 min continuous alarm; oversized buttons; bilingual Chinese/English output

ATEX-Certified Models

The PAU series was developed specifically for EU and ATEX-referenced markets. Both models carry Ex ia IIC T4 Ga ATEX certification and share a consistent IP68 protection rating. Certificate details are provided on request.

PASS Device  PAU-10 — Standard ATEX-certified PASS. Weight ≤230g. Continuous alarm time ≥450 min. It features a 1.54-inch LCD display, uses standard 3× AAA batteries for easy field replacement, and provides ≥300 cd/m² light visibility for reliable field operation.

PASS Device  PAU-20 — Compact and lightweight ATEX-certified PASS. Weight ≤190g. Continuous alarm time ≥400 min. It features an ultra-high ≥750 cd/m² light visibility and a high-strength housing with bulletproof rubber overmold, making it ideal for harsh and cross-border rescue scenarios.

How to choose: China fire procurement or projects accepting Chinese Ex-proof certification → GB-compliant models. EU, Middle East, chemical or ATEX-referenced explosive-atmosphere projects → ATEX-certified PAU series (choose PAU-20 for LCM display and higher visibility). Multi-market supply → one factory, two compliance platforms, customizable configuration.

In-House Laboratory: How We Prove the Claims

Claims are easy. Verification is harder. Our in-house laboratory includes a professional anechoic room, a deep-water tank for immersion and IP testing, rain test, salt spray test, high/low temperature test, constant-temperature test, drop test, high-temperature aging test, air-tightness test and high-temperature burn test. This allows us to validate acoustic performance, sealing, environmental durability and housing safety before mass production — and to iterate quickly when a standard or tender requirement changes.

For buyers, this means you can request more than a datasheet. You can ask for test reports, arrange a factory and laboratory review, or send a sample for your own validation.

OEM/ODM Customization: From Tender Requirement to Mass Production

As a factory-direct manufacturer with our own R&D team, we support customization at the platform, configuration and presentation levels:

  • Functional configuration: model selection, optional peripherals, communication modules and accessory pairing.

  • Language and interaction: voice prompts, interface language and bilingual output.

  • Housing and branding: color, logo, label, packaging and user manual.

  • Tender-specific configuration: parameter labeling, accessory kits and documentation packages.

  • OEM/ODM programs: prototype, lab validation, pilot run and mass production.

Typical flow: requirement review → standard and certification gap check → configuration or prototype → in-house lab validation → pilot run → mass production. If your project cites a standard outside our current certified scope, we will tell you at the review stage — not after the PO.

FAQ: Standards, Certification Scope, and Customization

1. Is GB 27900 equivalent to NFPA 1970?
No. They are different compliance systems. GB 27900—2026 defines a broader product platform including communication-type devices; NFPA 1970 keeps a narrower PASS functional boundary centered on alarm and RF communication. One does not replace the other.

2. Does ATEX certification also satisfy GB or NFPA?
No. ATEX controls admission into explosive atmospheres. It does not replace product performance standards. A device can carry both domestic Ex-proof and ATEX certification, but the certificates are separate.

3. Do all your PASS devices have Ex-proof certification?
All GB-compliant models carry domestic Ex-proof certification under the Chinese GB 3836 system. The PAU series carries ATEX certification for EU and ATEX-referenced markets. These are two separate certification systems. We do not publish certificate images or numbers online; contact us with your target market and model, and we will send the certificate that applies.

4. Are your models NFPA 1970 certified?
No. Our current certified scope covers GB 27900 with domestic Ex-proof certification for the GB-compliant models, and ATEX certification for the PAU series. We do not claim NFPA 1970 certification. If your tender cites NFPA 1970, contact us and we will clarify the scope honestly.

5. Can you customize for our tender?
Yes — at configuration, language, housing, branding, packaging and documentation levels. Share the tender requirement and target market, and we will confirm feasibility, certification scope and lead time.

6. Can we visit the factory or laboratory?
Yes. Factory and laboratory reviews can be arranged, and certification/test documents can be provided for verification.

Choose Your Compliance Path — and Talk to the Factory

If you already know your target market and tender standard:
Tell us the market and the standard cited in your tender. We will recommend the matching GB-compliant or ATEX-certified model and send the available certification documents.

Get a Standard-Matched Model Recommendation
Ask for the Ex-proof certificate that applies to your market — Chinese GB 3836 for GB-compliant models, or ATEX for the PAU series — and we will send it with the model recommendation.

If you need customization, multi-market supply or an OEM/ODM program:
Talk to the factory directly. Share your configuration, volume and certification requirements, and we will review feasibility with our R&D and laboratory team.

Discuss Custom / OEM Requirements with the Factory